HOUSKEEPING
- Combustible material should not be stored in boiler rooms, mechanical rooms or electrical equipment rooms.
- Combustible materials should not be stored in exits or exit enclosures.
- Outside dumpsters should be kept at least 5 feet away from combustible walls, windows, doors, overhangs and lid should be closed.
- Compressed gas containers, cylinders and tanks should be secured to prevent falling.
- Storage is not allowed near electrical panels or in electrical equipment rooms.
EXIT
- Exit ways and doors should not be visually or physically obstructed.
- Exit ways and doors should be unlocked when building is occupied.
- Emergency lighting systems should be functional.
- Fire assemblies should not be obstructed or otherwise impaired from their proper operation at any time.
- Main door should have a sign above door stating "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED."
- Exit door should not be blocked.
- Exit signs should be illuminated as required.
- Items should not be stored in hallways
Fire protection
- All fire lanes should be clear and unobstructed.
- Fire alarm systems should be serviced annually.
- Fire protection systems should be maintained in an operative condition at all times and repaired where defective.
- Fire hydrants and hose connections should not be blocked by items (i.e., idle pallets, etc.)
- Make sure fire department telephone numbers are conspicuous
- Make sure trash and debris are not lodged into piping and other locations
Building maintenance
- The building address should be clearly visible from the street, minimum 4 inches in height with a contrasting background.
- Fire-resistance-rated construction should be maintained.
- Emergency lighting must be tested every six months and records must be maintained on site
- Muster point should be clearly marked
- Designated smoking area to be identified
Electrical
- Extension cords and flexible cords should not be a substitute for permanent wiring.
- Electrical panels must not be obstructed.
- Electrical panel openings must be covered.
- Breakers that continue to trip should not be tied off.
- Power strips must be plugged directly into an outlet and NOT daisy-chained
- Power strips should be directly connected to a permanently installed receptacle.
- Power strip cords and extension cords should not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage.
Fire Extinguishers
- A minimum of one 2A-10:BC portable fire extinguisher should be provided within 75 feet of travel distance from anywhere in the business on each floor.
- Fire extinguishers should be inspected at least monthly.
- Fire extinguishers should not be obstructed and should be in a conspicuous location.
- When visually obstructed, an approved means should be provided to indicate location of fire extinguishers.
- Fire extinguisher should be mounted on the wall with a hanger.
On discovering Fire
1. raise
an alarm to alert others
2. call
fire service
3. evacuate
the building
4. shut
all doors behind you
5. never
try to pick any valuables or possession
6. do
not panic
7. do
not pull or push others
8. do
not run but walk out smartly
9. do
not use elevator or lift, it might fail. Use the stairs
10. follow the emergency exit nearest to
you
11. assemble at the designated muster point
12. make a roll call to ensure no one is
left in the building
13. never go back to the building until the
fire brigades tells you to do so
14.assist the fire brigade as much as you
can
Please call the fire safety department in Lagos state
Please call the fire safety department in Lagos state
S/N
|
DESIGNATION
|
NAME
|
PHONE
|
E-MAIL
|
1.
|
DIRECTOR | FADIPE RASAK IDOWU | 08028078847 | manfadip@yahoo.com |
2.
|
ASST. DIRECTOR | |||
4
|
ALAUSA FIRE STATION | CFS SHONEKAN M. |
08023528482 08033193826 |
|
5.
|
IKEJA FIRE STATION | CFS HUNGE G. A. | 08023129094 | hagtonamos@yahoo.com |
6.
|
IKOTUN /IGANDO FIRE STATION | ACFS ADESHIYAN O. A. | 08056455969 | Adashiyan@yahoo.com |
7.
|
EPE FIRE STATION | PFSI. JUBRI T.A | 08033410920 | Kingtaj4real@yahoo,com |
8.
|
BADAGRY FIRE STATION | PFSI ABIMBOLA M. O. |
08158669923 08025484963 |
Olayemi abimbola@yahoo.com |
9.
|
AGEGE FIRE STATION | ACFS AYANJOMPE OLUSEGUN | 08035720765 | Robert oluayan@yahoo.com |
10.
|
ISOLO FIRE STATION | CFS OLAOGUN D. G. | 08028252638 | Oladson @yahoo.com |
11.
|
ETI-OSA FIRE STATION | ACFS AJAYI M. | 08034036594 | Michael ajayi@50@yahoo.com |
12.
|
ILUPEJU FIRE STATION | CFS ADEKOYA F.A. |
08056462363 08022965494 |
|
13.
|
SARI – IGANMU FIRE STATION | ACFS OLOKUNGBOYE P. | 08023158200 | Polokungboye@yahoo.com |
14.
|
OJO FIRE STATION | CFS OLADIPUPO S. | 08025036279 | Alhajisena@yahoo.com |
15.
|
IKORODU FIRE STATION | CFS AYANGBESAN F. | 08028129154 | |
16.
|
ONIKAN FIRE STATION | ACFS FATAI R. O. |
No comments:
Post a Comment